Cannot delete a sub-estate from the console on a German-language computer - error: 0x8007000E

  • N.º del artículo: 116838
  • Actualizado: 12 may 2014

Issue

In the Enterprise Console, when trying to delete a sub-estate, the following error is shown (in the advanced dialog box):

A transient error has occurred.
----- [outer exception] -----
-- error: 0x8007000E
-- facility: Win32

at __w64 long __thiscall ManageSubEstatesPage::OnDelete(unsigned short,unsigned short,struct HWND__ *,int &)
at __w64 long __thiscall CMainFrame::OnManageRoles(unsigned short,unsigned short,struct HWND__ *,int &)
at int __cdecl Run(int,class bl::CommandLine,enum bl::ConsoleType::Type)
at int __stdcall wWinMain(struct HINSTANCE__ *,struct HINSTANCE__ *,wchar_t *,int)

First seen in

Enterprise Console 5.0.0

Operating systems
German-language platforms only.

Cause

The problem has been traced to an incorrectly formatted string in the German resource file of a user warning message which the console tries to display.

What To Do

We hope to resolve this issue in Enterprise Console 5.1 (currently in beta).  In the meanwhile the workaround available is to delete the sub-estate via a remote console installed on an non-German-language operating system.

 
Si necesita más ayuda, póngase en contacto con soporte técnico.

Valore el artículo

Muy malo Excelente

Comentarios