Integrity check for data area failed. System halted

  • Article ID: 109162
  • Updated: 30 Sep 2010


Product
Sophos SafeGuard Disk Encryption 4.60

Client OS

Windows 2000 Professional SP4, Windows XP SP3

Server OS

None

Question

What can cause the message: "Integrity check for data area failed. System halted" before the PBA is shown?

Answer

This message is shown when the "FIPS mode" feature is installed and the system kernel has been modified (accidentialy or on purpose) or is corrupted
(e.g. This prevents the boot of the machine after a potential attack to the kernel area).

Solution:

- Restore a valid kernel backup.

Not a solution:

- Start an emergency uninstallation, the decryption will not start in this case.


keywords: integrität prüfung sde Sophos SafeGuard Disk Encryption

 
If you need more information or guidance, then please contact technical support.