How to configure a simulated delay of credential handover in combination with SGSAL

  • Artikel-ID: 108176
  • Aktualisiert: 10 Jan 2008


Product
SafeGuard Easy multi-platform 4.40.1

Client OS

Windows 2000 Professional SP4, Windows XP SP2 Professional Edition

Server OS

Windows 2003 Standard Edition

Question

Is it possible to force a delay for SG SAL so that login credentials are not handed over to the Windows GINA immediately?

Answer

Since version 4.40.1, SafeGuard Easy provides the function to implement a simulated delay into the SAL logon procedure.

Please use following registry setting to do so:

[HKEY_LOCAL_MACHINE\SOFTWARE\Utimaco\SGEasy]
"SALMODE"=dword:00000000

Value range:

"0" -> no simulated delay will be used if 0 is choosen.
"1" to "60" -> a delay in seconds can be simulated with the values 1 to 60.
"61" and above -> If the value contains numbers higher then sixty, a delay in milliseconds will be simulated.


Additionally, the key will be filled by the setup routine with "0", even if its already present.


keywords: logon delay sge

 
Wenn Sie weitere Informationen oder Unterstützung benötigen, wenden Sie sich bitte an den technischen Support.

Artikel bewerten

Ungenügend Hervorragend

Anmerkungen